0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessAbstract An efficient reverse-phase high-performance liquid chromatographic method, based on the design of the experiment approach, was developed for the simultaneous determination of capsiate isomers. Critical method parameters, i.e., flow rate and mobile phase composition, demarcated during preliminary screening were optimized using central composite design. Chromatographic separation was achieved on a Nucleodur C18 column (250 × 4.6 mm, 5 μm), with the mobile phase consisting of water–acetonitrile (40:60), both acidified with 0.1% v/v formic acid, passed at a flow rate of 1 mL/min. E- and Z-capsiates were eluted from the column at the retention times of 18.56 ± 0.09 and 17.30 ± 0.08 min, respectively, with a resolution factor of 1.693 ± 0.046. The method was found to be linear within the concentration range of 1.054–5.270 and 8.623–43.115 μg/mL for Z- and E-isomers, respectively, with an R2 of >0.99. Recovery of the individual values was in range of 96.15–101.92%, with a relative standard deviation of <2%. The developed method was used to quantify capsiate isomers extracted from sweet pepper fruits. Therefore, the proposed method is presented for optimum isomeric resolution of these closely related E- and Z-isomers with convenient sample preparation, acceptable run-time, cost effectiveness and use of conventional instruments. Highlights
Reena Gupta, Bhupinder Kapoor, Monica Gulati, Sumant Saini, Pooja Rani, Atanas G. Atanasov, Stefano Dall’Acqua, Qushmua Alzahrani, Deepak N. Kapoor, Jesus Simal Gandara (2025). Quality by Design–Steered Chromatographic Separation and Identification of the Geometric Isomers of Capsiate by Reversed-Phase HPLC and LC-MS. , 63(2), DOI: https://doi.org/10.1093/chromsci/bmaf001.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2025
Authors
10
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1093/chromsci/bmaf001
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access