Get Free AccessOn the basis of brachytherapy experience, edge stenosis has been raised as a potential limitation for drug-eluting stents. We used serial intravascular ultrasound (IVUS) to prospectively analyze vessel responses in adjacent reference segments after implantation of polymer-controlled paclitaxel-eluting stents.TAXUS II was a randomized, double-blind trial with 2 consecutive patient cohorts that compared slow-release (SR) and moderate-release (MR) paclitaxel-eluting stents with control bare metal stents (BMS). By protocol, all patients had postprocedure and 6-month follow-up IVUS. Quantitative IVUS analysis was performed by an independent core laboratory, blinded to treatment allocation, in 5-mm vessel segments immediately proximal and distal to the stent. Serial IVUS was available for 106 SR, 107 MR, and 214 BMS patients. For all 3 groups, a significant decrease in proximal-edge lumen area was observed at 6 months. The decrease was comparable (by ANOVA, P=0.194) for patients in the SR (-0.54+/-2.1 mm2) and MR (-0.88+/-1.9 mm2) groups compared with the BMS (-1.02+/-1.9 mm2) group. For the distal edge, a significant decrease in lumen area was only observed with BMS (-0.91+/-2.0 mm2, P<0.0001); this decrease was significantly attenuated with SR (0.08+/-2.0 mm2) and MR (-0.19+/-1.7 mm2) stents (P<0.0001 by ANOVA). Negative vessel remodeling was observed at the proximal (-0.48+/-2.2 mm2, P=0.011) but not the distal edges of BMS and at neither edge of SR or MR stents.The marked reduction in in-stent restenosis with SR or MR stents is not associated with increased edge stenosis at 6-month follow-up IVUS. In fact, compared with BMS, there is instead a significant reduction in late lumen loss at the distal edge with TAXUS stents.
Patrick W. Serruys, Muzaffer Değertekin, Kengo Tanabe, Mary E. Russell, Giulio Guagliumi, John G. Webb, J Hamburger, Wolfgang Rutsch, Christoph Kaiser, Robert Whitbourn, Edoardo Camenzind, Ian T. Meredith, François Reeves, Christoph Nienaber, Edouard Benit, Clemens Disco, Jörg Koglin, Antonio Colombo (2004). Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents. Circulation, 109(5), pp. 627-633, DOI: 10.1161/01.cir.0000112566.87022.32.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2004
Authors
18
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.0000112566.87022.32
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access