Get Free AccessIn the last three decades protocols for the validation of blood pressure measuring devices have been developed by the US Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League, the European Society of Hypertension Working Group on blood pressure Monitoring and the International Organization for Standardization. The European Society of Hypertension International Protocol required much smaller sample size than the other protocols, aiming to reduce the time, resources and cost of validation studies and thereby increase the number of validated devices. Given its specifications, the European Society of Hypertension International Protocol was adequate for 'high- and low-accuracy' devices, yet assessment of 'moderate accuracy' devices had high uncertainty with resultant high rate of device failure. Thus, devices validated using the European Society of Hypertension International Protocol should be considered to be as accurate as those validated with the previous Association for the Advancement of Medical Instrumentation or British Hypertension Society protocols. However, the European Society of Hypertension International Protocol did not allow subgroup evaluation (arm sizes, special populations, etc). The mission of the European Society of Hypertension International Protocol to promote the concept of validation has been well achieved, as almost double studies have been published using it than all the other protocols together. However, the maintenance of different validation protocols is confusing and therefore experts from the Association for the Advancement of Medical Instrumentation, European Society of Hypertension International Protocol and International Organization for Standardization have now developed the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) as the recommended 21st-century procedure for worldwide application. The European Society of Hypertension Working Group has published a practical guide for using the Universal Standard. It is in the interests of all scientific bodies to propagate the Universal Standard and ensure its wide implementation.
Eoin O’Brien, George S. Stergiou, Paolo Palatini, Roland Asmar, John P A Ioannidis, Αναστάσιος Κόλλιας, Peter Lacy, Richard J. McManus, Martin G. Myers, Andrew Shennan, Ji‐Guang Wang, Gianfranco Parati (2019). Validation protocols for blood pressure measuring devices. , 24(4), DOI: https://doi.org/10.1097/mbp.0000000000000391.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2019
Authors
12
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1097/mbp.0000000000000391
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access