Get Free AccessAiming the assessment of novel, environmentally friendly corrosion inhibitors that can substitute chromate‐based ones, this work describes and validates a method for the rapid screening of water‐soluble inhibitors. The technique involves a fixed potential being applied between identical electrodes while immersed in an inhibitive solution and with the absence of a reference electrode. The current flowing between the electrodes is measured and the combined electrochemical response of the anodic and cathodic reactions, with and without the inhibitor, is then characterized. The incorporation of nine pairs of different metallic wires into a single assembly enables the effect of inhibitors on different metals to be assessed rapidly. The methodology presented allows approximately 30 electrochemical experiments to be performed per hour. In order to prove the usefulness of the proposed rapid screening technique (multielectrode), results obtained with the multielectrode are validated by comparison to the results obtained with a single electrode using only AA2024‐T3. The accuracy, reproducibility and parameter dependence has been assessed with the variation of inhibitor type and solution pH. Low absolute errors are found when studying inhibitors with good performance, giving confidence that no good inhibitors would be missed by this rapid screening method. The effect of cross‐contamination has been assessed and found to be negligible for almost all the pH range. Copyright © 2009 John Wiley & Sons, Ltd.
Santiago J. García, Tim H. Muster, A.E. Hughés, Paul White, D. Lau, T. Markley, T.G. Harvey, N. Sherman, Simon G. Hardin, P. Corrigan, A.M. Glenn, James I. Mardel, Herman Terryn, J.H.W. de Wit, J.M.C. Mol (2009). Validation of a fast scanning technique for corrosion inhibitor selection: influence of cross‐contamination on AA2024‐T3. Surface and Interface Analysis, 42(4), pp. 205-210, DOI: 10.1002/sia.3150.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2009
Authors
15
Datasets
0
Total Files
0
Language
English
Journal
Surface and Interface Analysis
DOI
10.1002/sia.3150
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access