0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessWe propose a novel multifrequency phase-modulation method for luminescence spectroscopy that uses a rectangular-wave modulated excitation source with a short duty cycle. It is used for obtaining more detailed information about the luminescence system: the information provided by different harmonics allows estimating a model for describing the global frequency response of the luminescent system for a wide range of analyte concentration and frequencies. Additionally, the proposed method improves the accuracy in determination of the analyte concentration. This improvement is based on a simple algorithm that combines multifrequency information provided by the different harmonics of the rectangular-wave signal, which can be easily implemented in existing photoluminescence instruments by replacing the excitation light source (short duty cycle rectangular signal instead of sinusoidal signal) and performing appropriate digital signal processing after the transducer (implemented in software). These claims have been demonstrated by using a well-known oxygen-sensing film coated at the end of an optical fiber [a Pt(II) porphyrin immobilized in polystyrene]. These experimental results show that use of the proposed multifrequency phase-modulation method (1) provides adequate modeling of the global response of the luminescent system (R(2) > 0.9996) and (2) decreases the root-mean-square error in analytical determination (from 0.1627 to 0.0128 kPa at 0.5 kPa O2 and from 0.9393 to 0.1532 kPa at 20 kPa O2) in comparison with a conventional phase-modulation method based on a sinusoidally modulated excitation source (under equal luminous power conditions).
Santiago Medina‐Rodríguez, Ángel de la Torre, F.J. Sainz-Gonzalo, Marta Marín‐Suárez, César Elosúa, Francisco J. Arregui, Ignacio R. Matı́as, Jorge F. Fernández‐Sánchez, Alberto Fernandez Gutierrez (2014). Improved Multifrequency Phase-Modulation Method That Uses Rectangular-Wave Signals to Increase Accuracy in Luminescence Spectroscopy. , 86(11), DOI: https://doi.org/10.1021/ac4030895.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2014
Authors
9
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1021/ac4030895
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access