0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessWaste materials are added to the ingredients of interlocking concrete masonry as a partial replacement for cement or sand to minimize resource depletion and environmental degradation while enhancing interlocking masonry characteristics. Rubberized concrete interlocking bricks (RCIBs) are newly developed interlocking masonry units, however, their bed-joint behavior is complex owing to the presence of waste materials and geometric imperfections. This study aimed to investigate the behavior of the dry-bed joint under compression and out-of-plane loading. Seven single-joint prisms (SJPs), five multiple-joint wallets (MJWs), and three RCIB hollow wall panels (HWPs) were prepared and tested under axial and out-of-plane lateral loading, respectively. The local contact stiffness of the bed joints in SJPs was found to be half of the stiffness of the prisms when the joint surface areas were almost in full contact. The maximum variation in the joint closure of the MJWs (0.68 mm) was 3.8 times higher than that of the SJPs (0.18 mm) owing to the multiple effects of contact-area irregularities and height differences between adjacent bricks. All the tested MJWs and SJPs exhibited similar joint-closure behavior during their initial compressive loading stages up to ∼0.65%–0.85% and 0.5%–0.7%, respectively, of the ultimate load. With a joint opening of 10.38 mm, the RCIB-HWPs achieved an ultimate lateral loading of 11.70 kN. The largest out-of-plane lateral loading validated the efficiency of the interlocking keys, which reduced brick slippage under lateral loading, indicating RCIB-HWPs stability.
Amin Al‐Fakih, Bashar S. Mohammed, Madyan A. Al‐Shugaa, Mohammed Al-osta (2022). Experimental investigation of dry-bed joints in rubberized concrete interlocking masonry. Journal of Building Engineering, 58, pp. 105048-105048, DOI: 10.1016/j.jobe.2022.105048.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2022
Authors
4
Datasets
0
Total Files
0
Language
English
Journal
Journal of Building Engineering
DOI
10.1016/j.jobe.2022.105048
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access