0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground:The edge vascular response (EVR) has been linked to important prognostic implications in patients treated with permanent metallic stents. We aimed to investigate the relationship of EVR with the geometric changes in the everolimus-eluting bioresorbable scaffold using serial optical coherence tomography (OCT) analysis.Methods and Results:In the first-in-man ABSORB trial, 28 patients (29 lesions) underwent serial OCT at 4 different time points (Cohort B1: post-procedure, 6, 24, and 60 months [n=13]; Cohort B2: post-procedure, 12, 36, and 60 months [n=15]) following implantation of the scaffold. In Cohort B1, there was no significant luminal change at the distal or proximal edge segment throughout the entire follow-up. In contrast, there was a significant reduction of the lumen flow area (LFA) of the scaffold between post-procedure and 6 months (−1.03±0.49 mm2[P<0.001]), whereas between 6 and 60 months the LFA remained stable (+0.31±1.00 mm2[P=0.293]). In Cohort B2, there was a significant luminal reduction of the proximal edge between post-procedure and 12 months (−0.57±0.74 mm2[P=0.017]), whereas the lumen area remained stable (−0.26±1.22 mm2[P=0.462]) between 12 and 60 months. The scaffold LFA showed a change similar to that observed in Cohort B1.Conclusions:Our study demonstrated a reduction in the scaffold luminal area in the absence of major EVR, suggesting that the physiological continuity of the lumen contour is restored long term. (Circ J 2016; 80: 1131–1141)
Hiroki Tateishi, Pannipa Suwannasom, Yohei Sotomi, Shimpei Nakatani, Yuki Ishibashi, Erhan Tenekecioğlu, Mohammad Abdelghani, Rafael Cavalcante, Yaping Zeng, Maik J. Grundeken, Felipe N. Albuquerque, Susan Veldhof, Yoshinobu Onuma, Patrick W. Serruys (2016). Edge Vascular Response After Resorption of the Everolimus-Eluting Bioresorbable Vascular Scaffold – A 5-Year Serial Optical Coherence Tomography Study –. Circulation Journal, 80(5), pp. 1131-1141, DOI: 10.1253/circj.cj-15-1325.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2016
Authors
14
Datasets
0
Total Files
0
Language
English
Journal
Circulation Journal
DOI
10.1253/circj.cj-15-1325
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access