0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessA constructal tree-shaped microchannel network for maximizing the saturated critical heat flux in a disc-shaped planar body has been investigated. n 0 radial channels touch the center and n p channels touch the periphery. Designs with no pairing level ( n 0 = n p ), one pairing level ( 2 n 0 = n p ) and two pairing levels ( 4 n 0 = n p ) have been studied. The fluid simulated is R-134a at a saturation temperature of T sat = 30 °C with no inlet subcooling. The flow enters at the center and exits at the periphery. The theoretical CHF model of Revellin and Thome [R. Revellin, J.R. Thome, A theoretical model for the prediction of the critical heat flux in heated microchannels, Int. J. Heat Mass Transfer 51 (2008) 1216–1225], specially developed for micro and minichannels, has been modified and used for predicting the wall CHF of low pressure refrigerants flowing in microchannels. The constraints are the disc radius R and the total volume of ducts V. The degrees of freedom are n 0 , n p and the mass flow rate m ˙ . In each case, the minimum global fluid flow resistance design has been adopted as proposed by Wechsatol et al. [W. Wechsatol, S. Lorente, A. Bejan, Optimal tree-shaped networks for fluid flow in a disc-shaped body, Int. J. Heat Mass Transfer 45 (2002) 4911–4924]. Maximizing the base CHF means increasing the number of central tubes for a given complexity. Furthermore, it is better to use a simple radial structure (with no pairing level) and 2 n 0 central tubes than a design with one pairing level and n 0 central tubes. On one hand, simplified structures seem to be roughly better for maximizing the base CHF. On the other hand, coupling the base CHF and the pumping power leads to different conclusions. There exists an optimal n 0 and n p to maximize the base CHF for each range of pumping power. For instance, for low pumping power, using radial ducts without pairing level is the best solution for dissipating high base CHF whereas for higher pumping power, a more complex design is beneficial with greater n p . In conclusion, the recommended complexity is modest (not maximal), and high complexity is not necessarily the best solution.
Rémi Revellin, John R. Thome, Adrian Bejan, Jocelyn Bonjour (2008). Constructal tree-shaped microchannel networks for maximizing the saturated critical heat flux. International Journal of Thermal Sciences, 48(2), pp. 342-352, DOI: 10.1016/j.ijthermalsci.2008.06.009.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2008
Authors
4
Datasets
0
Total Files
0
Language
English
Journal
International Journal of Thermal Sciences
DOI
10.1016/j.ijthermalsci.2008.06.009
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access